Stop processes gracefully, even on Windows. Library and command line tool.
On Windows it can:
- Send Ctrl + C to console applications
- Send Ctrl + Break to console applications
- Close graphical applications, including packaged UWP apps, as if their window was closed
- Send messages to standard input of console applications to answer questions such as "Y/N?"
On Linux and macOS it can:
- Send
SIGINTto applications - Send messages to the terminal of an application (
TIOCSTI, usually needs root)
On every platform it can kill a process, wait for it to exit and list its descendants.
Download an archive for your system from the
releases page (Windows x86_64 / ARM64, Linux
x86_64 / ARM64 static builds, macOS Intel / Apple silicon), check it against SHA256SUMS and put
terminator somewhere in your PATH.
Or install it from crates.io, where it is published
as process-terminator (the name terminator is taken). The installed command is still called
terminator:
cargo install process-terminator
Or build the latest source yourself:
cargo install --git https://github.com/SCP002/terminator
terminator stop <PID>... [-m ctrl-c|ctrl-break|close-window] [-t] [-w <MS>] [-f]
terminator kill <PID>... [-t]
terminator send <PID> <TEXT> [-n] [-e]
terminator tree <PID>
terminator wait <PID> [-w <MS>]
terminator stop 1234 --wait 3000 --force # Ctrl+C, then kill if still alive after 3 s
terminator stop 1234 --tree # every descendant first, then the process
terminator send 1234 "Y" --newline # answer "Terminate batch job (Y/N)?"
Exit codes: 0 success, 1 operation failed, 2 bad usage, 3 process still running.
The crate is on crates.io as process-terminator,
but the library itself is named terminator, so the code uses terminator::...:
cargo add process-terminator
use std::time::Duration;
use terminator::{kill, stop, wait_for_stop, Method};
fn main() -> terminator::Result<()> {
let pid = 1234;
stop(pid, Method::CtrlC)?;
if !wait_for_stop(pid, Some(Duration::from_secs(3))) {
kill(pid)?;
}
Ok(())
}See the examples folder and the API documentation on
docs.rs (or cargo doc --open).
A process can be attached to only one console, and reaching a foreign console means attaching to it. Detaching from your own console first can destroy it. The crate therefore picks the cheapest route that is safe:
| Caller | Target | Route | What happens |
|---|---|---|---|
| shares the target's console | same console | Direct |
Generate the event right here |
| has no console | any console | InProcess |
Attach, send, detach (under a lock) |
| has its own console | another console | Helper |
A short-lived detached helper attaches, sends |
The helper is the current executable, re-launched with a marker argument. A C runtime
initializer that the crate registers (.CRT$XCB) recognizes the marker before main and exits
after doing the job, so:
- there is no embedded proxy binary and nothing is written to the temporary folder;
- you do not have to call anything from
main: any binary that can spawn a helper contains the initializer by construction; - it runs before
ctor/inventorystyle initializers.
If the code is loaded as a DLL into a foreign host (Python extension, plugin), the host cannot be
re-launched. Use terminator::set_helper(Helper::Path(..)) to name an executable that links
terminator, for example terminator.exe. Without it you get Error::HelperUnavailable that says
so. A helper that does not understand the protocol is killed after 10 seconds and reported.
Set TERMINATOR_DEBUG=1 to print the chosen route.
Notes:
child_treeleaves outconhost.exe/OpenConsole.exe: Windows lists the console host as a child of every console application, but it is not part of the program's own process tree.- Ctrl+C and Ctrl+Break reach every process attached to the target console that has not disabled them, not only the target process.
- A process that was started with Ctrl+C disabled (
CREATE_NEW_PROCESS_GROUP, or a parent that calledSetConsoleCtrlHandler(NULL, TRUE)) passes that on to its children, and such a process ignoresctrl-c. Usectrl-breakorclose-windowfor it. - A UWP app has no top-level window of its own, so
close-windowfinds theApplicationFrameWindowthat hosts it and closes that, like the close button does. - A target that is elevated while the caller is not may fail with "access denied".
cargo test
CI runs the same command on Linux, macOS and Windows.
The end-to-end tests run the real CLI in each console state (own console, no console, shared
console) against a small victim process (examples/victim.rs) that records what it observed,
and check both the outcome and the route taken. They use hidden consoles, but window.rs needs an
interactive desktop session. cargo test -- --ignored additionally opens the Calculator to check
that packaged (UWP) apps can be closed by pid.
The test suite runs on every push in GitHub Actions on Linux (x86_64), macOS (Apple silicon) and Windows (x86_64). Release builds for Windows ARM64, Linux ARM64 and macOS Intel are produced by the same workflow but are not run by it; x86 Windows and other Unix systems are untested.
Not covered by the automated tests: sending text to a terminal on Linux and macOS (TIOCSTI,
which needs a terminal and usually root, and is disabled by default on recent Linux kernels), and
closing a UWP app. The latter was checked by hand on the Calculator (an ignored test, see above).