An integrated in-situ monitoring system for metal additive manufacturing: measurement, fusion, control — and a closed-form bound on what any detector could possibly see.

This repository is the code base for the LPBF/DED monitoring work, extended with a decision layer that the original system did not have. The two halves answer different questions and are kept apart on purpose:

half question where
measurement chain given these sensors, what process state is this? CODE/, driven by ammonitor
decision layer given this sensing chain, what could any detector achieve, and what would it cost? src/dbound/, wrapped by ammonitor.decision

The classifier stages report accuracy. The decision layer reports the ceiling that accuracy is measured against. A 97% score means nothing if the flaws it misses sit below the resolution limit; the bound says where that limit is.

Twin library: the decision half

This repository has a twin. The decision layer is the standalone package detectability-bound, created in the same effort to solve this repository's problem: a monitoring system that reports accuracy cannot say whether the defects it misses were visible at all, so the decision half was built to supply that statement. It is released as Zenodo v0.1.1 (doi:10.5281/zenodo.24136698, concept 10.5281/zenodo.24080212). This repository consumes it: a copy is vendored at src/dbound/ (code identical to upstream 81d99a2, released as v0.1.1) and wrapped by ammonitor.decision.

dbound — decision half this repository — measurement half
question what can any detector achieve, and at what cost? what does this sensing chain measure?
content bound and asymptotes, PSF/energy model, detector set, XCT estimators, design rule measurement chain, stage registry, provenance partition, six public datasets
artefacts its own manuscript, results and DOI the integrated manuscript, 36 stages, figures, this DOI
relationship defines the ceiling produces the measurements the ceiling constrains

The code dependency runs one way: dbound knows nothing about the monitoring chain, and this repository never edits the vendored copy except to sync it. The provenance is sibling, not parent and child — same author, same architecture, cross-cited. The code-level binding is src/ammonitor/decision.py (energy → bound.energy_at, POD → ndtr(d′ − z), inversion → required_voxel), and a test asserts that the wrapper and the package agree. The full mapping — module by module, result by result, versions and sync policy — is in docs/TWIN_LIBRARIES.md.

Start here

if you want to… read
understand what the system is and where each number comes from docs/使用说明.md (中文)
see how the two twin libraries fit together docs/TWIN_LIBRARIES.md
install it, place data, run stages, use the decision layer docs/GUIDE.md
know what may be cited as process evidence docs/PROVENANCE.md
understand the layering and data contracts docs/ARCHITECTURE.md
get the datasets data/README.md

Sixty seconds:

pip install -e .
python -m ammonitor list        # 36 stages; a leading ! means data absent
python -m ammonitor report      # what may be claimed, by provenance
pytest -q                       # 21 passed

Architecture

                ┌──────────────────────────────────────────────────────┐
   sensors      │  acoustic emission · laser ultrasound · phase/point  │
                └───────────────┬──────────────────────────────────────┘
                                │
                ┌───────────────▼───────────────┐
   measurement  │  feature extraction           │   CODE/1_acoustic
                │  classification               │   CODE/2_laser_ultrasound
                │  fusion (Kalman)              │   CODE/3_fusion
                │  phase unwrap / point cloud   │   CODE/4_phase_pointcloud
                │  closed-loop control          │   CODE/5_control
                └───────────────┬───────────────┘
                                │  stage registry, provenance-tagged
                ┌───────────────▼───────────────┐
   decision     │  d' = ΔI√E / σ                │   src/dbound
                │  POD ≤ Φ(d' − z_{1−α})        │   ammonitor.decision
                │  inverse: L_max, energy_needed│
                └───────────────┬───────────────┘
                                │
                ┌───────────────▼───────────────┐
   report       │  what may be claimed, by     │   ammonitor.report
                │  provenance category         │
                └───────────────────────────────┘

The decision layer in one paragraph

For a known signal in additive noise, the matched filter maximises the deflection d' = ‖s‖/σ, and no detector — including any trained one — can exceed POD = Φ(d' − z_{1−α}) (Neyman–Pearson plus Cauchy–Schwarz). What differs by modality is only where ‖s‖² comes from. For a volumetric flaw of diameter a imaged with point-spread width L, ‖s‖² = E(a/L) and

d' ∝ (a/L)³     below the voxel size        d' ∝ (a/L)^{3/2}   above it

so one halving of the voxel size is worth 64 repeat scans in the first regime and 8 in the second. For a transient event — an acoustic burst, a laser-ultrasound echo — ‖s‖² is simply the squared norm of the expected waveform, so what matters is how many samples the event occupies rather than how fine the grid is.

Quick start

pip install -e .
python -m ammonitor list          # 36 stages with provenance and data status
python -m ammonitor report        # what may be claimed, by category
python -m ammonitor bound --a 100 --L 40 --dI-over-sigma 5
pytest -q                         # 21 tests

ammonitor list marks stages whose declared input data are absent with !. Nothing runs silently on missing data.

Worked examples

Volumetric, from the command line — a 100 µm flaw imaged at 40 µm, contrast five times the noise:

d' = 9.50      POD bound = 1.000      largest admissible voxel for POD 0.9: 66.1 µm

Transient, on the measured EPFL acoustic set (31 401 waveforms × 5 000 samples, three classes). Taking each class mean as the expected waveform and the within-class residual as the noise the detector faces:

class n d' POD at α = 0.01
1 300 4.0 0.956
2 300 4.1 0.959
0 300 4.2 0.970

Reproduce with python tools/ae_detectability.py --data-root <path> --set D1. A deflection of four is a POD of 0.96 and no more: class means are only marginally separable, which is why the measurement chain needs features rather than templates.

Provenance is a first-class property

Every stage is tagged by what it runs on, and the reporter will not merge the categories:

category stages may be cited as
measured 14 evidence about the process
simulated 9 evidence about the method only
derived 13 neither; statistics and figures

The simulated fusion, unwrapping, point-cloud and closed-loop control modules are simulation studies — they carry np.random seeds and no measured capture — and are labelled as such. The measured counterparts that produced the paper's fusion, unwrapping, height-map, graded-decision and clutter numbers are separate stages in CODE/7_measured_real/. Averaging a simulated result with a measured one into a single "system accuracy" is precisely the mistake ammonitor report exists to prevent. See docs/PROVENANCE.md.

Repository layout

CODE/                     the analysis scripts (unchanged where they produced figures)
CODE/7_measured_real/     the real-data re-analyses of the fusion, unwrapping,
                          height-map, graded-decision and clutter results
src/ammonitor/            orchestration: registry, pipeline, decision, report, CLI
src/dbound/               the detectability bound: E(x), d', inversion, real-data kappa
tests/                    registry integrity, provenance/data coverage, decision math
tools/                    stage scanner (generates stages.json), acoustic demo
docs/                     architecture and provenance
data/                     datasets are not committed; see data/README.md

src/ammonitor/stages.json is generated from the source by tools/scan_stages.py, and a test asserts that every .py under CODE/ appears in it. A script cannot be added without the system noticing.

Datasets

dataset modality size source
EPFL acoustic emission AE, 3 classes, 31 401 × 5 000 4.5 GB Zenodo 10449883
Cranfield laser ultrasound LUT, FMC array 45 MB doi:10.17862/cranfield.rd.15190191
ORNL Peregrine coupons 4 process channels + tensile test 11 MB Zenodo 23727492
Fringe projection phase-stepped fringes + PUMA truth 41 MB Zenodo 22125908
WLI height maps 4 DED tracks, 480 × ~20 000 px 1.0 GB Zenodo 21285367
XCT AlSi10Mg 212 slices, 37 µm voxels 127 MB Zenodo 17602110

None is committed. Place them under data/ as described in data/README.md; the registry tells you which stages need which.

What this repository adds

  1. A decision layer that states the sensing chain's ceiling and its cost, applied to both the volumetric and the transient modality with one bound.
  2. A machine-generated stage registry with a provenance tag per stage, so the system cannot quietly mix measured and simulated evidence.
  3. An explicit claim partition (ammonitor report): what is process evidence, what is method evidence, what is neither.

The analysis scripts in CODE/ are unchanged where they produced published figures; that is deliberate. The real-data re-analyses added for v1.1.0 sit beside them in CODE/7_measured_real/ and write the result files the paper's tables are generated from.

Measured analyses added since v1.0.0

Four of the paper's tables are computed from public captures that the v1.0.0 package mentioned only in prose. They are now stages, each with its dataset DOI in the docstring and its output in results/:

result stage reproduces
fusion 7_measured_real:run_fusion_real RMSE 38.20 / 37.43 / 36.03 MPa; 302.30 and 512.67 build-held-out
unwrapping 7_measured_real:run_unwrap_real 0.532 mm over 6.2 mm; no refinement improves it
height maps 7_measured_real:run_pointcloud_real 2.9–5.0 µm robust deviation; no 10 µm window
graded decision 7_measured_real:run_decision_real AUC 0.751; 0.54–0.93 per build; enrichment 2.25
clutter κ 7_measured_real:run_xct_clutter 23–125 across 1–16 voxels; 0.530/0.117/0.023 detector PODs
spectral bound 1_acoustic:run_ae_spectral 88.9 % ± 0.3 %; d′ 2.83–3.12 at 64 bands
laser-ultrasound echo 7_measured_real:run_lu_echo d′ 16.4 / 6.0; κ 0.99 / 0.98; POD 0.838 / 0.427
design rule 6_visualization:run_design_rule Table 1 reproduced to the digit

The six manuscript figures are drawn from these files by 6_visualization:run_ndte_figures, which reads the registry live so the system figure cannot quote counts the registry no longer has.

Citation and licence

Code: MIT. Datasets keep their own licences. If you use this system, cite the underlying paper and the dataset records above.

About

Twin of detectability-bound: integrated in-situ monitoring for metal AM, 36 provenance-tagged stages, six public datasets, and the decision half (dbound).

Topics

Resources

Stars

4 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages